Automating heat pump flexibility: results from a pilot
This means that reduced space heating demand will not be likely to cause higher hot water demand – because heat pumps should have already satisfied any outstanding hot water demand. We used a variety of methods to understand different aspects of participants’ experience of the events, including how acceptable they found their heat pumps being remotely controlled. The rebound period is typically caused by lower external temperatures reducing the efficiency of the heat pump during a period where there is a call for heat to raise internal temperatures within a short period of time. In the flexibility window, the smart thermostat would then change the setpoint to the minimum acceptable temperature. At the beginning of the pre-heating window, the smart thermostat would call for heat from the heat pump in an attempt to reach a predefined maximum acceptable temperature for each household.
We recorded their internal temperatures and heat pump electrical consumption, and collected feedback on their experience via weekly surveys and two rounds of AI-powered interviews. Two areas that we felt needed to be explored in greater detail were other household members’ experiences, and possible impacts to hot water availability during events. The aim of this window was to increase the internal temperature of participants’ homes, with the hypothesis that the additional retained heat would then improve comfort during the flexibility window which followed. Whilst we chose not to explore this within the HeatFlex UK pilot, we are curious whether acceptability might be increased through well-chosen messages. These findings support other research that temperature perception is a complex process, including many factors that may be different across our sample of participants, and across different events. In the HeatFlex UK pilot, we treated thermal comfort as if it was ‘non-negotiable’, in order to understand how much electricity demand could be reduced without compromising it.
We successfully increased participants’ internal temperatures in our preheat period and decreased them in the peak period Moreover, through the interviews we aimed to explore the lived experiences of participants, including how they felt and behaved within their homes, and overall obtaining a more nuanced understanding than we could achieve using purely quantitative data. The basic premise of our intervention was that the operation of the heat pump could be controlled by setting internal temperatures at levels to either increase consumption or decrease consumption. We found that internal temperatures in the Treatment group increased by, on average, 0.85°C during the preheating period. We used a variety of data sources to understand how the internal temperature of homes changed, and the impact this had on participants, including surveys, interviews and temperature data collected by the smart thermostat.
The greater increase in temperatures during February could be due to the extension of the preheat period from two to four hours, or other factors like slightly warmer exterior temperatures. In February/March, the treatment group experienced an average increase of 0.70°C in the preheat period and an average decrease of 0.48°C in the peak period. In January, the treatment group experienced an average increase of 0.29°C in the preheat period and an average decrease of 0.24°C in the peak period. We used a quasi-experimental design to estimate the impact of our intervention on households’ heat pump consumption To assess the viability of automated flexibility in type-of-use tariffs, we sought to explore the following thematic the published PDF areas.
This section aims to explore whether we were able to maintain the thermal comfort of participants, as our use of setpoints was intended to do. It is worth noting that the coldest external temperature during a flexibility window was 3.5°C, so household experiences may have changed in colder conditions. Indeed, we encouraged them to opt out if they felt uncomfortable during events, or to opt out before an event started if they were not going to be at home. Participants described a range of factors that influenced their attitude towards the remote control aspect of the trial. So the cost is difficult to calculate because obviously prices are going up.” However, they did not “think [that] the first year we were unsatisfied.
We found that the vast majority of participants would be happy with automation being introduced to their current tariff, although some found additional incentives to be necessary. We successfully managed to shift a significant proportion of our samples’ heating demand away from a peak period between 4pm-7pm, on consecutive days every Monday to Friday through the winter months of January to April. This research trialled the incorporation of automated flexibility into Heat Pump Plus, developing our understanding of how optimised heating schedules can be used to shift demand resulting from space heating away from peak periods on the grid.
We conducted the randomisation process before installing our monitoring devices and smart thermostats on a group of 137 willing households. The Treatment group took part in the HeatFlex events, with their heat pumps remotely controlled; the Control group only had their household and heat pump consumption measured without taking part in events. As a result, 33 of the participants had a heat pump monitor successfully installed along with the smart thermostat, while 10 had the smart thermostat only. However, we faced interoperability issues when installing the smart thermostat, which ultimately limited our sample size.
During the pre-heating window, it is higher than normal consumption due to additional heating. This report summarises a small-scale pilot we used to test and refine a heat pump flexibility intervention where we remotely took control of participants’ heat pumps for short periods of time we refer to as ‘events’. Nesta partnered with Centre for Net Zero on HeatFlex UK – a project to pilot and develop a trial to investigate heat pump flexibility, consumer preferences and how these are affected by third-party automation and pre-heating. Using energy flexibly will help reduce demand on the grid at peak times, which means that carbon-intensive forms of generation will need to be deployed less often.
Predicted effect of heat pump penetration on half-hourly British electricity demand on a very cold winter day. In the UK, supply will be dominated by wind power, and demand will peak in winter evenings (as it does today), but the electrification of heat, transport and industry will change the demand profile, including the potential introduction of a new winter morning peak created by heat pumps (see Figure 1). Generate citations for any assignment in thousands of styles, including MLA, APA, Chicago and Harvard. This would also provide grid management services, reducing the need for expensive infrastructural upgrades, and helping to decarbonise our energy system as we reduce our reliance on carbon-intensive sources of electricity generation.